Product Detail
5 in 1 Digital Multimeter Sound Level Humidity Luminosity Temperature LCD AC/DC Multimeter Volt Amp Ohm Tester EM5510 ALL SUN
5 in 1 Digital Multimeter Sound Level Humidity Luminosity Temperature LCD AC/DC Multimeter Volt Amp Ohm Tester EM5510 ALL SUN
5 in 1 Digital Multimeter Sound Level Humidity Luminosity Temperature LCD AC/DC Multimeter Volt Amp Ohm Tester EM5510 ALL SUN
5 in 1 Digital Multimeter Sound Level Humidity Luminosity Temperature LCD AC/DC Multimeter Volt Amp Ohm Tester EM5510 ALL SUN
5 in 1 Digital Multimeter Sound Level Humidity Luminosity Temperature LCD AC/DC Multimeter Volt Amp Ohm Tester EM5510 ALL SUN

5 in 1 Digital Multimeter Sound Level Humidity Luminosity Temperature LCD AC/DC Multimeter Volt Amp Ohm Tester EM5510 ALL SUN

  • Quantity
5 in 1 Digital Multimeter Sound Level Humidity Luminosity Temperature LCD AC/DC Multimeter Volt Amp Ohm Tester EM5510 ALL SUN
Specifications
  • Item No.
  • COBD28359
  • Shipping
  • Free Shipping
  • Weight
  • 500g
Description
5 in 1 Digital Multimeter Sound Level Humidity Luminosity
Temperature LCD AC/DC Multimeter Volt Amp Ohm Tester EM5510

Note :
This package doesnot include batteries.
Due to new rules of China Post Air, parcels must not include batteries,
otherwise it will not get through the custom.


> This multimeter is 4000 count, 3 3/4-digit multimeter.
> It can be used to measure DC and AC voltage, DC and AC current,
resistance, capacitance, frequency, diode, temperature, continuity,
duty cycle and electromagnetic field radiation.
> It can be used as a test tool for environment and devices.
> It is a high-performance and versatile meter.









Safety Information >>>

This meter has been designed according to IEC-61010 concerning electronic measuring
instruments with a measurement category (CAT II 600V) and pollution degree 2.


GENERAL SPECIFICATION
>>>
> Display: 3 3/4-digit LCD, with a max. reading of 3999
> Overrange Indication: "OL" shown on the LCD
> Negative Polarity Indiaction: "-" displayed automatically
> Sampling Rate: 2-3 times/ sec
> Operating Temperature: 0-40 ℃, <75%RH
> Storage Temperature: -30-60 ℃, <85%RH
> Operating Altitude: 0 to 2000 meters
> Power: 9V battery (6F22)
> Dimensions (W×L×T): 83×162×47 mm
> Weight: 310g (with battery)
Accuracy is specified for a period of one year after calibration and
at 18℃ to 28 ℃, with relative humidity <75%. Normally, accuracy
specifications take the form of: ±([% of Reading]+[number of Least
Significant Digits])

DC Voltage >>>

Range

Resolution

Accuracy

400mV

0.1mV

±(1.0%+5)

4V

1mV


±(0.8%+3)


40V

10mV

400V

100mV

600V

1V

±(1.0%+5)
Input Impedance: the 400mV range: >1000MΩ
the other ranges: 10MΩ
Max.Permitted Input: 400Mv range: 250V DC or AC
the other ranges: 600V DC or AC
AC Voltage >>>

Range

Resolution

Accuracy

4V

1mV

±(1.0%+5)

40V

10mV

400V

100mV

600V

1V

±(1.2%+5)
Input Impedance: 10MΩ
Max.Permitted Input: 600V DC or AC
Frequency Range: 40Hz ~400Hz
Response:Average, calibrated in rms of sine wave

DC Current >>>

Range

Resolution

Accuracy

400uA

0.1uA


±(1.2%+3)


4000 uA

1 uA

40mA

10 uA

400mA

100 uA

4A

1mA

±(1.8%+3)

10A

10mA

±(2.0%+5)
Overload Protection:
For "MA℃” jack inputs: Fuse, 500Ma/ 250V, fast action
For "10A" jack inputs: no fuse
Max. Input Current: 10A (For inputs>5A:
measurement duration<10 secs,
interval>15minutes)
Max. Voltage Drop: 400mV

AC Current >>>


Range

Resolution

Accuracy

400uA

0.1uA


±(1.5%+5)


4000 uA

1 uA

40mA

10 uA

400mA

100 uA

4A

1mA

±(2.0%+5)

10A

10mA

±(2.5%+5)
Overload Protection:
For "MA℃” jack inputs: Fuse, 500Ma/ 250V, fast action
For "10A" jack inputs: no fuse
Max. Input Current: 10A (For inputs>5A:
measurement duration<10secs,
interval>15minutes)
Max. Voltage Drop: 400mV
Frequency Range: 40Hz~400Hz
Response: Average, calibrated in rms of sine wave

RESISTANCE >>>


Range

Resolution

Accuracy

400Ω

0.1Ω

±(1.0%+5)

4kΩ



±(1.0%+3)


40 kΩ

10Ω

400 kΩ

100Ω

4MΩ

1kΩ

40MΩ

10kΩ

±(2.0%+5)
Overload Protection: 250V DC/ AC
Open Circuit Voltage: about 0.25V

FREQUENCY >>>


Range

Resolution

Accuracy

10Hz

0.01Hz

±(1.0%+3)

100Hz

0.1Hz


±(0.8%+3)

1kHz

1 Hz

10kHz

10 Hz

100kHz

100 Hz

±(1.0%+3)

200kHz

1kHz

>200kHz

Not specified
Input voltage: 1 Vrms~20 Vrms
Overload Protection: 250VDC/AC

CAPACITANCE(use Relative mode) >>>


Range

Resolution

Accuracy

4nF

0.001nF

±(4.0%+5)

40nF

0.01nF

400nF

0.1nF

4uF

1nF

40uF

10nF

100uF

100nF

±(8.0%+5)
Overload Protection: 250V DC/ AC

TEMPERATURE >>>


Range

Resolution

Accuracy

-20℃~400℃

0.01℃

±1.5%±3℃

400℃~1000℃

1℃

±2.0%±3℃
Overload Protection: Fuse, 500Ma/250V, fast action

DUTY CYCLE >>>


Range

Resolution

Accuracy

1%~99%

0.1%

1Hz~10kHz:±(2.0%+5)

>10kHz: not specified
Input Voltage: 3Vp-p~10Vp-p
Overload Protection: 250V DC/AC

HUMIDITY(%RH) >>>


Range

Resolution

Accuracy

30%~90%

0.1%

---------------------
Working Temperature: 0~40 ℃
Response Time: 45% RH→90%RH less than or equal to 10minutes
90% RH→45%RH less than or equal to 15minutes

SOUND LEVEL(dB) >>>

Range

Resolution

Accuracy

35~100dB

0.1dB

---------------------------------
Frequency: 100~10000Hz

INTENSITY OF ILLUMINATION(Lux) >>>


Range

Resolution

Accuracy

400x10 Lux

1 Lux

---------------------------------

4000x10 Lux

10Lux

ACCESSORIES >>>
Test Lead; Temperature probe; Battery; Users Manual; Holster

Reviews 0
Write a Review
  • * Rating
    * Gender
    * Your Name
    * Your E-Mail
    * Review Detail

Previous: EM8910 Digital Multimeter Multi tester Backlight AC/DC Ammeter Voltmeter Ohm Portable Meter voltage meter

Next: PH Meter Plant Flowers Soil Moisture Light tester hydroponics Analyzer Farming ETP300A ALL SUN